www.ratio.nl 28 www.ratio.nl In the setup LOAD BAL you can choose between: SETUP CHG MODE <- DISABLED -> SETUP CHG MODE <- MASTER -> SETUP CHG MODE <- SLAVE 1 -> SETUP CHG MODE <- SLAVE 2 -> SETUP CHG MODE <- SLAVE 3 -> You can change the setup by pressing the left or right arrow button. After your choice has been made confirm by pressing the middle button. You can only use load balancing in SMART mode. 3 SETUP I-MAX HOME Here you can set the maximum available current of your house. To set MAX Mains current you can choose between 10A and 99A. This setup is available in SMART mode. 4 SETUP I-MIN SETUP <- I-MIN -> Here you can set the minimum charging current. You can choose between 6A and 16A with steps of 1A. The standard setting is 6A. To make your choice please use the left or right arrow button. To confirm press the middle button. 5 SETUP I-MAX SETUP <- I-MAX -> Here you can set the maximum charging current for the EV. You can choose between 10A and 32A with steps of 1A. To make your choice please use the left or right arrow. To confirm press the middle button.